Pioneer Water Tanks: The Benefit of Storing Water For Fire Protection Under NFPA 22
- July 11, 2024
Pioneer Water Tanks: The Benefit of Storing Water For Fire Protection Under NFPA 22 with Brandi Whitaker, Account and Business Development Manager
As presented at the 2024 NFPA National Fire Protection Association in Orlando, Florida. Link to follow.
What is NFPA 22?
The NFPA® 22 Standard for Water Tanks for Private Fire Protection sets the minimum requirements for the design, construction, installation, and maintenance of water tanks and their accessories.
The NFPA Committee on Gravity Tanks established the Standard on Gravity Tanks in 1909, with subsequent amendments and revisions adopted up to 1950. Over time, the standard broadened to encompass tanks beyond gravity tanks, including metal tanks, pressure tanks, and tank heating.
The 1993 edition introduced environmentally friendly requirements for tank-coating systems applicable to metal tanks. New chapters were added to cover the design and erection of bolted steel tanks, concrete tanks, and fiberglass tanks, aligning with contemporary water storage tank design practices.
Subsequent editions, including those in 1996, 1998, 2003, 2008, and 2013, addressed issues such as tank care, maintenance, corrosion resistance, and environmental concerns specific to metal tanks. Changes were made to improve user-friendliness and align with industry standards, including updates to sizing requirements, acceptance test procedures, and terminology definitions for metal tanks.
Wild Fires
During a wildfire, access to water for firefighting efforts is essential. Backup water sources, such as tanks or reservoirs, provide firefighters with additional water to suppress flames, protect property, and prevent the spread of the fire.
Wildfires can disrupt or damage infrastructure, including water supply systems. Having backup water protection ensures redundancy in the water supply, reducing reliance on potentially vulnerable primary water sources. This redundancy is critical for maintaining firefighting capabilities, especially in remote or rural areas where access to water may be limited.
Knowing that there is a backup water source available in case of a wildfire provides peace of mind to residents, businesses, and emergency responders. It adds an additional layer of preparedness and can contribute to more effective wildfire responses.
Job Name: Madera Travel Center
Model: XL 25/03 Pioneer Water Tank in Surfmist® COLORBOND® steel
Location: Madera, California
One tank will act as a reserve for fire protection in case of an emergency. The water supply will feed a fire sprinkler system pump adjacent to the tank. The pump provides pressurized water to the truck stop building.
Location: Anaheim, California
Model XLE 50/03 Pioneer Water Tank
This fire protection system was required by Orange County for fire flow. The commercial fire protection system was installed on-site in two days with a proprietary jacking system. The system was installed in November 2018 with a 100,000-gallon effective capacity for fire protection.
Public Supply is not Sufficient
In areas with low water pressure, installing a hydrant may necessitate costly upgrades to the water supply system to ensure adequate pressure for firefighting purposes. A water storage tank can provide consistent water pressure regardless of external factors, potentially eliminating the need for expensive pressure upgrades.
Private residences and businesses can fight fires with the safety of water stored on site when public systems might not have enough water or the ability to connect water to the location.
Rainwater Harvested Fire Tanks can act as a backup when there is no water on site to use.
NFPA 22 Chapter 4 – Water Sources (4.2):
The water source for filling the tank needs to be adequate and dependable, with allowance for its reliability in the future. Suppose the water supply from a public service main isn’t adequate in quality, quantity, or pressure (measured in fire flow for fire protection). In that case, an alternative water source needs to be provided (like an extra water storage tank on the property).
NFPA 13 A.23.2.1(g)
The capture of rainwater is generally not considered a problem since NFPA 13 has long allowed the use of open lakes, rivers, and ponds, which are nothing more than an open collection of rainwater and melted snow.
Job Name: Hunt Volunteer Fire Department
Model: XLR 30/02 Pioneer Water Tank
Location: Hunt, Texas
The Hunt Volunteer Fire Department utilizes a Pioneer Water Tank to fill up trucks and as an onsite water source. The antivortex nozzles and engineering of the tank enable the immense amount of pressure needed to fill up trucks.
NFPA 1142 in relation to NFPA 22
NFPA 1142 specifies water supplies for firefighting purposes in rural and suburban areas. This is typically defined as within areas that have less than 500 – 1000 people per square mile. If the water structure is unable to supply a minimum of 250gpm at 20psi above the average domestic use, supplemented water supplies may be required. The NFPA 1142 standard may also be implemented whenever the AHJ, the authority having jurisdiction, requires it.
Pioneer Water Tanks are utilized as water supplies for firefighting, following NFPA 1142. Pioneer Water Tanks are a reliable water supply that stands ready to provide water consistently in case of emergencies and for daily domestic use. The wide array of fire connections is configurable based on the project requirements including antivortex nozzles and hydrant hookups.
“Cisterns should have a minimum usable volume as determined by the AHJ, based on the methods described in Chapter 4. There is no real limit to the maximum capacity.” NFPA 1142 Annex B.4.1
Job Name: Central Community Volunteer Fire Department
Location: Weatherford, TX
Model XLR23/02 to be used at the fire station.
Included: Fire fittings are included on the Pioneer Water Tank that will store rainwater for later use at the fire station.
Location: Briggs, Texas
Model Two XLR 23/02 Pioneer Water Tanks
Water was used to refill water trucks for the Briggs Texas Fire Department using rain catchment from the roof of the building.
Cost Effective
Residences and businesses have used water tanks in lieu of other fire fighting requirements such as Sprinklers or adding a hydrant to a property in order to save cost up front and over time.
Installation Costs:
Water tanks typically have lower installation costs compared to sprinkler systems. Sprinkler systems require extensive piping, fittings, and labor for installation throughout the building, while water tanks can often be installed externally with simpler plumbing connections.
Installing a hydrant requires not only the hydrant itself but also underground piping to connect it to the water supply system. This piping can be costly, especially if the property is far from existing water mains. In contrast, a water storage tank may require less infrastructure, depending on its location relative to the property.
Maintenance Costs:
While the initial investment in a water storage tank may be higher than installing a hydrant, the long-term costs of maintenance and operation can be lower. Water storage tanks typically require less maintenance and have lower ongoing operational expenses compared to hydrants, which may require periodic testing, maintenance, and repairs.
Water tanks generally have lower ongoing maintenance costs than sprinkler systems. Sprinkler systems require periodic inspections, testing, and maintenance to ensure they are functioning correctly, which can incur additional expenses over time.
Job Name: Austin Wood Recycling
Model: XLR50/02 Pioneer Water Tank
Location: North Hays County Texas
Water was used for Fire Protection required by the local Fire Marshal. The Pioneer Water Tanks with accessories fulfilled the requirement for the building permit.
Job Name: Icehouse
Location: Krum, TX
Model XLE23/02 – Required for their business
Included: 6″ Outlet w/ Anti-Vortex Plate and 6″ OS&Y Gate Valve, Fixed Ladder & Access Hatch, Roof Vent, 6″ Overflow, Level Gauge, and Auto-refill Float Valve for filling with well water.
Location: North Hays County Texas
Model: Two XLR50/02 Pioneer Water Tanks
Water was used as a dual purpose for both fire fighting and domestic potable water. The tank is approved by the North Hays County Fire Marshal’s office for a letter to the homeowner’s insurance company to assist with a discount for having water available to fight a fire.
Contact your local Pioneer Water Tanks Dealer
Pioneer Water Tanks America operates with a network of accredited providers and installers for localized service.
Call or fill out the contact form to be connected with the closest provider today.
For advice on setting up a rainwater harvesting system, contact the team at Pioneer Water Tanks on (877) 223-7784 or fill in our form to enquire online.