California NFPA 1142 Water Supplies with Pioneer Water Tanks

Thank You for Reaching Out

We Will be in Touch Soon

Pioneer Water Tanks are utilized as water supplies for firefighting throughout the State of California, in accordance with NFPA 1142. Pioneer Water Tanks are the reliable water supply that stands ready to provide water consistently in case of emergencies and for daily domestic use. The wide array of fire connections are configurable based on the project requirements including antivortex nozzles and hydrant hookups.

 

We offer optional permit packages with local independent consultant engineer wet-stamped cover letters per project.

Pioneer Water Tanks

for Firefighting Applications in California

 

Properties without an adequate water source for firefighting can utilize Pioneer Water Tanks, in accordance with the California Fire Code and the NFPA 1142 standard. NFPA 1142 specifies water supplies for firefighting purposes in rural and suburban areas.

If the water structure is unable to supply a minimum of 250gpm at 20psi above the average domestic use, supplemented water supplies may be required. The NFPA 1142 standard may also be implemented whenever the AHJ, the authority having jurisdiction, requires it.

 

Areas without existing adequate and reliable water supply systems, as determined by the AHJ, can supplement or add a water storage tank to fulfill requirements. The local authority determines the capacity needs, based on the fire flow equation stated in the local fire code.

 

“Cisterns should have a minimum usable volume as determined by the AHJ, based on the methods described in Chapter 4. There is no real limit to the maximum capacity.” NFPA 1142 Annex B.4.1

 

Pioneer Water Tanks have engineering packages available for standard capacities. Our qualified engineering personnel and independent consultant engineers can also provide a stamped cover letter per project, as well as provide documentation as required.

 

“The design of the cistern must be submitted to the AHJ for approval prior to construction. All plans must be signed by a licensed/registered professional engineer.” NFPA 1142 Annex B.4.3.5

Cost-effective dual-purpose tank for multiple water needs

Complies with NFPA requirements for fire protection water tanks

NSF-61 Certified AQUALINER® Fresh tank liner keeps water fresh and clean (learn more)

DUAL USE WATER TANKS

Pioneer Water Tanks are cost-effective for dual purposes and are approved for fire protection and drinking water storage. Dual service water storage tanks can be used for fire protection, irrigation, as a potable drinking water source and more applications. Ensure adequate water supply is ready in case of an emergency with the appropriate fire connections for residential and commercial needs. This is typically achieved with two separate plumbing systems being implemented with the water tank. The plumbing pipe for the separate use does not extend below the water elevation that is reserved for fire protection.

We can deliver and install water storage tanks from 5,000 to 1,000,000-Gallons. Pioneer Water Tanks are backed by our industry-leading 20-Year warranty so you can rest easy knowing you have a water storage solution that will last.

NFPA 1142 Fire-Flow Requirements for Buildings, Determining the Water Tank Capacity Requirements

The fire flow calculation covered in NFPA 1142 is intended for areas without available water systems, where a supplemented or additional water supply is required. The NFPA 1142 method employs the volumetric capacity of the specific structure to calculate the minimum water supply.

The NFPA 1142 fire flow formula is:

Minimum water supply (MWS) = (Total structure volume) ÷ (Occupancy hazard classification number) * Construction classification number

The AHJ has the final say to capacity and connection requirements. Pioneer Water Tanks work well with local specifications and have permit packages ready.

TESTED AND PROVEN

Pioneer Water Tanks are manufactured to NFPA 22 requirements and have been third-party tested and proven.

The NFPA 22 Standard for Water Tanks for Private Fire Protection sets the minimum requirements for the design, construction, installation, and maintenance of water tanks and their accessories.

DISCOVER THE DIFFERENCE IN PIONEER WATER TANKS

HEAVY-DUTY TRUSSES

 

Our exclusively engineered trusses are hot-dipped galvanized steel equipped with a swivel foot. As a result, it provides optimal movement in your tank in extreme conditions. As your tank adapts to external conditions, you can rest easy your tank won’t fail when you need it most.

HIGH TENSILE BOLTS

 

Specifically engineered for strength and durability, our bolts are galvanized high tensile 8.8 grade. Not only are they hardened and super strong, but they are also the most resistant bolt on the market to shear under pressure.

PIONEER V-LOCK®

 

Our exclusive PIONEER V-LOCK® is specifically engineered to maximize the strength of corrugated steel without damaging or stretching your liner when molded to the tank wall. Independent testing proves that the PIONEER V-LOCK® provides the ultimate shock absorption to prevent movement or sinking.

FIRE HOSE FITTINGS

 

Be ready for fire emergencies with our fast, convenient firefighting valve options. Outfit your tank with anti-vortex fittings and firefighting adapters for quick access during a fire emergency.

Pioneer Water Tanks America offers our standard water storage tank models with the option to upgrade or addon accessories

 

Tank CodeUS GallonsDiameter

XLE 10/02

10,00017′ 7″

XLE 13/02

15,00019′ 9″

XLE 15/02

20,24322′ 0″

XLE 23/02

29,09326′ 4″

XLE 30/02

39,62630′ 9″

XL 40/02

51,78535′ 2″

XL 50/02

65,56739′ 6″

XL 50/03

97,14839′ 6″

Custom Sizes

CustomDesigned to Project
NSF 61 Approved Pioneer Water Tanks for potable water

NSF 61 Certified

NFPA 22 Pioneer Water Tanks for firefighting

Commercial Accessories

AQUALINER® Fresh

Engineering Packages

Pioneer Water Tanks horizontal logo

916-287-8873

 