California Custom Water Tanks

Designed for the Project Needs

Call Now 916-287-8873

8 am – 5 pm

     

    Customized Pioneer Water Tanks

     

    Pioneer Water Tanks America offers a wide range of custom water storage tanks with diameter, tank wall height, capacity options. Pioneer Water Tanks can be configured for high-wind locales, seismic conditions, and heavy industrial zones with additional accessories that exceed different compliance needs.

     

    Engineered Design Options

     

    Our qualified engineering personnel and independent consultant engineers are available to configure a water storage tank to the project requirements. We listen to the project-specific needs and recommend a suitable custom water storage solution that is approved for use in California.

    Pioneer Water Tanks Capacity and Size Chart

    Pioneer Water Tanks America capacity chart

    ONLY PIONEER HAS OVER 30-YEARS OF PROVIDING…

    1. The AQUALINER® Fresh, the only antimicrobial tank liner in the world.

    2. The PIONEER V-LOCK® tank wall profile provides the strength of corrugated steel and maintains support for the liner while minimizing stress.

    3. The industry-leading 20–year conditional warranty on the tank and liner.

    4. The heavy-duty roof truss system, manufactured for extreme conditions.

    5. Our standard accessories and commercial upgrades expand the functionality of your tank.

    Pioneer Water Tanks are engineered for durability with commercial options for wind and snow load requirements. Commercial water storage systems utilize the heavy-duty roof that is structurally designed to enable mounting of features such as a vent hatch and or platforms.

     

    Pioneer Water Tanks can be configured to the project application with our commercial accessory options. Our engineering packages work with local engineering consultants to provide for the permitting.

    Pioneer Water Tanks accessories

    PIONEER WATER TANKS ACCESSORY OPTIONS

    Expand the functionality of your water storage system with our commercial accessory options. Pioneer Water Tanks can be configured to the project requirements with the option to add our engineering package for permitting.

    Pioneer Water Tanks are engineered to NFPA standards for water storage for fire protection. The tank body and roof are made of Zincalume® Steel, which is proven to withstand fire immersion. The tank’s firefighting adapters and nozzles are compatible with fire hoses across California.

     

    Pioneer Water Tanks can be configured for cyclonic and seismic conditions, as well as heavy industrial zones. Additional accessories are available for different compliance needs. Outfit your tank with anti-vortex fittings and firefighting adapters for quick access during a fire emergency. Our engineering packages are available for permits where required for water tanks.

    FIRE HOSE FITTINGS

     

    Be ready for fire emergencies with our fast, convenient firefighting valve options. Outfit your tank with anti-vortex fittings and firefighting adapters for quick access during a fire emergency. Learn More about Pioneer Fire Protection

    COLORBOND® Color Options for Pioneer Water Tanks

    Only the highest quality Zincalume® and Colorbond® steel is used in Pioneer Water Tanks, providing unmatched durability that no other tank manufacturer can offer- that’s why Pioneer® Tanks last longer than any other brand.

     

    Pioneer Water Tanks come standard in Zincalume® Steel with your option of upgrading to a wide selection of Colorbond® steel color options. Colorbond® steel color options expand into many different color lines.

    NSF 61 Approved Pioneer Water Tanks for potable water

    NSF 61 Certified

    NFPA 22 Pioneer Water Tanks for firefighting

    Commercial Accessories

    AQUALINER® Fresh

    Engineering Packages

    Call Now 916-287-8873

    8 am – 5 pm

       

      Pioneer Water Tanks Foundations

      The foundation for Pioneer Water Tanks depends on the location and application of the water storage project. Pioneer Water Tanks may have the option to sit on a clean sand pad base or may be required to be anchored to a concrete ring beam depending on the local authority.

      This short video shows a concrete ring beam being installed for a 51,785-Gallon Pioneer Water Tank in Nothern California.

      Concrete ring beam outline for Pioneer Water Tanks

      The ring beam drawings specify the size, number and spacing of the reinforcing bars and ligatures to be used as well as the MPA rating for the concrete. Ring beams should be as level as possible and have no more than +/- 1/16” over any 5’0” (+/- 2mm over any 2m) of the circumference at the tank wall position and +/- 1/8” (+/- 4mm) over the entire ring beam. A survey chart will need to be completed and returned to your local installer for approval before the construction is started.

      Concrete ring beam for Pioneer Water Tanks

      The local Pioneer Water Tanks installer needs to ensure that foundation conditions are adequate. All water storage systems are subject to the local authority requirements so Pioneer Water Tanks also recommends local installers adhere to that authority for the tank location.

      Pioneer Water Tanks America offers our standard water storage tank models with the option to upgrade or addon accessories

      Tank CodeUS GallonsDiameter

      XLE 10/02

      10,00017′ 7″

      XLE 13/02

      15,00019′ 9″

      XLE 15/02

      20,24322′ 0″

      XLE 23/02

      29,09326′ 4″

      XLE 30/02

      39,62630′ 9″

      XL 40/02

      51,78535′ 2″

      XL 50/02

      65,56739′ 6″

      XL 50/03

      97,14839′ 6″

      Custom Sizes

      CustomDesigned to Project

      Pioneer Water Tanks horizontal logo

      916-287-8873

       

      Sacramento, California 95448